Larger foundations
Pedestals sized for wind and mesh load at full height; up to 4.5 × 4.5 × 1.8 m at Wasit.
Perimeter fences and closed-roof enclosures from 10 to 30 m high. We handle design support, civil foundations, erection, mesh installation and tensioning as one package.

One package
Our crews work inside live Saudi Aramco gas plants, under Aramco permit-to-work, lifting and HSE requirements.
We deliver anti-drone passive protection fences as one package: survey and setting-out, above-ground RC foundations, anchor-bolt setting, post erection, wire-rope and mesh installation, final tensioning and handover.
1,470linear metres under our 2026 orders at Fadhili, Wasit and Hawiyah
10–30 mfence heights covered: 10, 15, 20 and 25 m delivered, posts rated to 30 m
4anti-drone fence projects in 2026, three for Saudi Aramco and one for ACWA Power
Two systems
3D renders are indicative. Final geometry is always per the approved IFC drawings.

A vertical mesh wall with a cranked top toward the attack side. Protects substations, GIS buildings, pipe racks and plant boundaries from side approach.

Lattice towers carrying double side mesh 2 m apart and double roof mesh 4 m apart, per the new SAIS parameters. Protects tanks, spheres and compact critical equipment from attack from above.
Height range
Pick a height to see a Type A fence drawn to scale next to a person, and where we are building it.
25m
Wasit Gas Plant and Hajr Power Plant
Pedestals up to 4.5 × 4.5 × 1.8 m at Wasit. At Hajr, the 25 m fence was delivered from survey to commissioning.
Type B section
Outer and inner mesh on all four sides and over the roof, so the enclosure covers attack from the top and every side.
| Element | Parameter |
|---|---|
| Side mesh | Outer and inner layer, 2 m apart, fixed to the outer and inner faces of the lattice towers |
| Roof mesh | Outer layer at tower top; inner layer 4 m below, both on tensioned catenary cables |
| Towers | Square lattice towers on above-ground RC pedestals; each carries both side layers and the roof cables |
| Height | To suit the protected asset, per approved drawings |
| Plant fit | Towers stay outside bund walls and clear of fire-water and drain lines |
Foundations
| Item | Typical specification |
|---|---|
| Pedestal sizes | 3.2 to 4.7 m square × 1.8 m (e.g. 3.5 m at Fadhili, 4.5 m at Wasit) |
| Concrete | C40/30 SRC on 100 mm blinding over compacted sub-base |
| Reinforcement | Approx. 90 kg/m³, cut, bent and fixed on site |
| Anchor bolts | Cast-in assembly set to template and survey coordinates |
| Base plate | Non-shrink grout, stiffened post base |
| Mass pours | Early-morning pours, chilled mix water, temperature monitoring, extended wet curing |
Sizes from our Fadhili and Wasit proposal; final sizes per IFC drawings.

Pedestals sized for wind and mesh load at full height; up to 4.5 × 4.5 × 1.8 m at Wasit.
Cranes and man-lifts with approved lift plans and certified riggers.
Ropes tensioned and checked for sag, alignment and clamp torque.
Execution
Every front runs to the approved method statement and inspection and test plan (ITP).

Set out post positions to IFC coordinates; locate buried services.
Excavate shallow, compact, and cast 100 mm blinding.
Rebar, formwork and anchor-bolt template; pour C40/30 SRC.
Check bolt levels; non-shrink grout under base plates.
Erect with crane to the lift plan; plumb and torque.
Fix Ø16 mm horizontal, vertical and diagonal ropes.
Lift, join and fix DT mesh with spirals and clamps.
Final tension, sag and torque check; close all comments.
HSE and quality
Project references
| Project / site | Client · end user | Height | Quantity | Status |
|---|---|---|---|---|
| Fadhili & Wasit Gas Plants: NAGO Facilities Passive Protection | Nabil A. Abu Nhaya & Partner · Saudi Aramco | 15–30 m (Fadhili 20 m, Wasit 25 m) | 435 LM | Ongoing |
| Fadhili Gas Plant: additional fence line | Nabil A. Abu Nhaya & Partner · Saudi Aramco | 20 m | 100 LM | Ongoing |
| Hawiyah Gas Plant: ADF mesh installation | Saad Ali Al-Essa Group for Contracting · Saudi Aramco | 10 m and 15 m | 935 LM | Ongoing |
| Hajr Power Plant: Qurayyah Power Plants Complex | Hajr for Electricity Production Co. (ACWA Power) | 25 m | Full ADF system | Completed* |
* The Hajr purchase order was issued to SIT Arabian Contracting Co. Ltd.; the fence was delivered by the same project management team.
Why Al-Kameyat
Fences at 10, 15, 20 and 25 m, with orders covering posts up to 30 m.
Foundations, erection, ropes and mesh under one contractor and one programme.
A Dammam base close to Eastern Province plants, with crews already working at Aramco sites.
Perimeter fences and double-layer closed-roof enclosures on lattice towers.
Permit-to-work, lift plans and ITP hold points as standard on every front.
Rate per linear metre on jointly measured, approved quantities.
FAQ
A tensioned steel-mesh barrier on steel posts or lattice towers that intercepts drones before they reach critical plant equipment. Type A is a perimeter (side) fence; Type B is a closed-roof enclosure with double mesh on the sides and roof.
From 10 m to 30 m. In 2026 the company has delivered or is building fences at 10, 15, 20 and 25 m, with posts rated up to 30 m.
Type A is a vertical mesh wall on cranked tubular steel posts that protects substations, GIS buildings, pipe racks and plant boundaries from side approach. Type B uses lattice towers with double side mesh 2 m apart and double roof mesh 4 m apart to protect tanks, spheres and compact equipment from attack from above.
Above-ground reinforced concrete pedestals, typically 3.2 to 4.7 m square by 1.8 m, in C40/30 SRC on 100 mm blinding, with cast-in anchor bolts and non-shrink grout. They avoid deep excavation in live plant areas.
At Hawiyah Gas Plant the programme for 935 linear metres of 10 m and 15 m fence mesh installation is 10 working days from site handover.
By rate per linear metre, on jointly measured and approved quantities.
Send us the drawings, heights and linear metres. We’ll come back with a method, programme and rate per linear metre.