Electrical & instrumentation
LV/MV power distribution, calibration and commissioning.
Design, installation and maintenance of internal and external fiber-optic networks and cross-site cabling, with fusion splicing and full OTDR testing.

Overview
When buildings, campuses or process plants need data or control links, we design the route, pull the cable, splice it and prove it.
We install single-mode OS1 and multimode OM1, OM2 and OM3 cables, with full OTDR testing for a complete solution. Projects range from communication cables to plant control cabling for process and control systems.
Our fiber-optic engineers are MOD-cleared and experienced in petrochemical, industrial and MOD environments. We have installed hundreds of kilometres of external fiber, including cross-site single pulls of more than 5 km.
Light-buffered and loose-tube fibers, and CST armoured fiber-optic cables.
| Type | Mode | Core / cladding |
|---|---|---|
| OS1 | Single-mode | 9/125 µm |
| OM1 | Multimode | 62.5/125 µm |
| OM2 | Multimode | 50/125 µm |
| OM3 | Multimode | 50/125 µm |
Fiber selection starts with fiber type, which depends on the transmission distance and bandwidth required, for example 1 Gb Ethernet. Getting it right at the start meets both performance and environmental requirements.
We carry out a free site survey and design the fiber route or network for your project, so the cable we specify suits your current and future needs.
Available nationwide.
We can use existing ducts, build a new duct and pit system, or advise when aerial fiber or wireless is more cost-effective.
We terminate single-mode (9/125 µm) and multimode (62.5/125 µm and 50/125 µm) cables on site, whether we installed them or not, with ST, SC, MTRJ or FC/PC connectors to suit the equipment.
Our preferred method is fusion splicing pre-terminated pigtails onto the main cable for minimal loss, presented in a patch panel and rack, a wall-mounted box or an industrial hazardous-area termination enclosure.
FAQ
Single-mode OS1 (9/125 µm) and multimode OM1 (62.5/125 µm), OM2 and OM3 (50/125 µm), in light-buffered, loose-tube and CST armoured constructions.
We have a track record of cross-site single pulls of more than 5 km, and have installed hundreds of kilometres of external fiber.
Yes. Every installation can be completed with full OTDR testing, and we offer fusion splicing, Pedcap joining and LSPM fiber proving.
Send us your scope, drawings or bill of quantities. Our project team will review it and come back to you with a proposal.